Roof Ventilation Calculator

Enter attic floor area to get the net free ventilating area your roof needs, balanced between soffit intake and ridge exhaust, plus how many vents that means.

Code requires 1 square foot of net free ventilating area per 150 square feet of attic floor, or 1 per 300 when a vapour retarder is present and intake and exhaust are balanced. Half must be intake at the soffit and half exhaust at the ridge.

Calculate attic ventilation

Net free area is the open area of a vent, not its physical size.

sq ft

1:300 requires balanced intake and exhaust.

sq in/ft

Check the product spec sheet.

sq in each

Total net free area

1,440 sq in

square inches required

Intake required 720 sq in
Exhaust required 720 sq in
Ridge vent needed 40 ft
Soffit vents needed 80
Balanced attic ventilation: intake low, exhaust high A cross-section through a gable attic. Vents in the soffit at both eaves admit outside air. The air rises along the underside of the roof deck, carrying heat and moisture with it, and exits through a continuous vent at the ridge. Intake and exhaust each take half of the required net free area, because exhaust without matching intake pulls air from the house below instead. Ridge vent, 50% exhaust Soffit intake, 25% Soffit intake, 25% Attic
Net free area is a budget to split, not just a total to hit. Roughly half belongs at the ridge and half at the eaves. Exhaust without matching intake does not ventilate the attic harder, it pulls conditioned air up out of the house through every ceiling gap it can find.

Net free area is not vent size

A vent that measures 16 by 8 inches does not provide 128 square inches of ventilation. Louvres, screens and baffles block most of the opening. The usable figure is net free area, published by the manufacturer, and it is often less than half the physical dimension.

Always size from the NFA on the spec sheet. Sizing from the physical opening is the most common way an attic ends up under-ventilated despite looking well vented from the ground.

Balance matters more than total

Ventilation works by convection: cool air enters low at the soffit, warms, and leaves high at the ridge. That only happens if intake at least equals exhaust, which is why the vent type you choose matters as much as the total area. An attic with generous ridge venting and blocked soffits will pull its makeup air from inside the house instead, dragging conditioned air and moisture into the attic.

Under-ventilated attics cook shingles from below and shorten their life, and in cold climates they are the direct cause of ice dams, because warm attic air melts snow that then refreezes at the cold eave. If you have recurring ice dams, ventilation and insulation are the fix, not heat cable.

Frequently asked questions

How much roof ventilation do I need?

One square foot of net free area per 150 square feet of attic floor, halved between intake and exhaust. With a vapour retarder and balanced venting, the ratio relaxes to 1:300.

What is net free area?

The actual open area of a vent after louvres and insect screening, published by the manufacturer. It is typically well under half the vent's physical dimensions.

How many soffit vents do I need?

Divide the required intake NFA by the NFA of one vent. A 1,500 sq ft attic needs 720 sq in of intake, which is 80 vents at 9 sq in each, or a continuous strip vent instead.

Can you have too much roof ventilation?

Excess exhaust without matching intake is genuinely harmful. It short-circuits, pulling air from the house or from other roof vents rather than the soffits. Balance matters more than raw quantity.

Do ridge vents work without soffit vents?

Barely. A ridge vent needs low intake to draw from. Without open soffits it will pull makeup air from the living space below, carrying moisture into the attic.

Related calculators